617 Power Supply

617 Power Supply

Share
Our Price £400.00
Reward Points 2000
Quantity

Description

For use as replacement for older 600 systems where 717 is not compatible.

The main power and control unit for the Intercall 600 system. It connects to the mains supply and incorporates full battery back up to safeguard the system in the event of a mains supply failure. It also stores the text programming information and can be used to configure the system by simply connecting a laptop computer. An alternative power supply unit is required for larger installations and is designed to increase the permitted number of units and quantity of cable allowed on one system.

Related Products...

L714 Remote Sounder with Relay

If you need an audible alarm to attract attention, but don't need an indication of the call location, the L714 is the simple solution. The sounder is similar in operation to a display unit with a multi level alarm, but has limited zoning facilities. Any assistance or emergency call on the system will over-ride the standard call tone. A built-in relay provides normally open and normally closed 'dry' contacts, which can be used to trigger auxiliary devices.

£75.00

L737 Booster PSU

The Booster Power Supply unit is designed to increase the permitted number of units and qunatity of cable that an be used on any one system. Only one master power supply may be connected on any one system but several booster units may be connected as required. Booster power supply unit to be used in conjunction with 617 and 717 power supply units.

£400.00

L730 Slave Infra-Red Unit

Slave infra-red receiver which can be linked into other call points.

£43.00

KS1 Isolating Keyswitch

Used to isolate monitoring devices such as PIR1 or door contact.

£20.00

LBAT Backup Battery

12V 2.1aH battery for L717, L617 and L737 power supply unit.

£25.00

M1 Magnetic Door Contact

Installed in conjunction with door monitoring unit or call point and isolation switches. Activates paired call point when door is opened.

£12.00

L622 Standard Call Point

A call point is needed for every individual call location on the system. Every L622 unit features five levels of call, multi-colour re-assurance LED alerts and a 'call follower' sounder. The jack socket accepts inputs from a wide range of triggering devices such as pear leads, pressure mats and portable radio triggers. A magnetic reset option is also available (order code L622M) which only allows the reset function to be activated by the use of a magnetic key.

£39.50

PIR1 Passive Infra Red Bed Monitor

If you need to monitor a resident's bed and alert staff when he or she is on the move, the PIR1 bed monitor will detect movement and alert the staff. However, the bed itself is 'masked' out of the range of the detector so that it only monitors movement outside the bed area. Any movement within the receiver's range will activate a call, and trigger the call point.

£39.00

SCP Slave Call Point

Designed for use in one room or ward where each individual bed doesn't need a separate identity on the call system. The unit features a call button, pear lead jack socket and re-assurance indicator.

Units must be connected to a standard call point to generate the call identity and to provide the reset. Slave call points can only generate a standard call from either the call button or pear lead socket.

£22.00