The website uses cookies to allow us to better understand how the site is used. By continuing to use this site, you consent to this policy. Click to learn more. 
    
 

Altec 169 Mhz Temp Extreme Sensor

Altec 169 Mhz Temp Extreme Sensor

Share
Our Price £99.52
Reward Points 497
Quantity

Manufacturer Tynetec

Description

The Temperature Extreme Sensor should be wall mounted in the hallway or living room away from any draughts or heat sources. This will provide early warning of extreme low or high household temperatures which could result in the occupier suffering hypothermia or dehydration. In addition, the building will also be protected against burst pipes or potential fire hazards.

Features include

  • Solid state temperature sensing element
  • Lower alarm temperature: 5 degrees C for 30 minutes
  • Upper alarm temperature: 30 degrees C for 5 minutes
  • Rate of rise alarm temperature: 8 degrees C per minute
  • 3 years battery life (typical) - user replaceable 3.6V Lithium
  • Daily battery self test & low battery reporting
  • Dimensions: 84 x 84 x 36 mm (HxWxD)
  • Temperature Extreme Sensor Part No. ZXT426
  • Compatible with SayPhone, Advent xt & Altec Response

Related Products...

Epilespy Monitor

The Epilepsy Monitor bed sensor pads should be positioned under the mattress to detect arm and leg movements. If a Tonic Clonic seizure is detected in the bed an alarm call is transmitted.

Features include

  • 2 under mattress sensor pads
  • Sophisticated digital processor
  • 3 sensitivity settings
  • LED indication of sensitivity setting
  • Supplied with Mains Adapter
  • 5 Years Transmitter battery life (typical)
  • Daily battery self test & low battery reporting
  • Dimensions: 125 x 69 x 24 mm (HxWxD)
  • Epilepsy Monitor Part No. ZXT441
  • Compatible with SayPhone, Advent xt & Altec Response

Air Activated Switch

The Air Activated switch can be used in wet areas such as swimming pools or Jacuzzi's. The actuator pad is connected via PVC tubing to a wall mounted switch plate. An alarm call is made by simply squeezing the pad once.

£69.38

Altec 169Mhz Flood Detector

Flood Detectors should be located on the floor below the bath, wash basin or kitchen sink or anywhere a tap could be left running. Flood Detectors can be free standing or screw fixed to the skirting board with an optional mounting bracket. If a flood is detected an alarm call will be transmitted.

Features include

  • Moisture Bridge Sensor
  • Activated LED indicator
  • 5 years battery life (typical)
  • Daily battery self test & low battery reporting
  • Dimensions: 50 x 95 x 18 mm (HxWxD)
  • Flood Detector Part No. ZXT424
  • Optional Mounting Bracket Part No. V00770
  • Compatible with SayPhone, Advent xt & Altec Response

£58.37

Chair Sensor

The Chair Sensor should be positioned under the seat cushion, monitoring periods are set on the Sensor Controller. If a person sits down, then gets up again and does not return within the preset time an alarm call will be transmitted. A table lamp can be turned on/off automatically using a Remote Controlled Mains Switcher Kit. All "in-chair" and "out-of-chair" activity is transmitted and logged.

Features include

  • Chair sensor dimensions: 325 x 130 mm
  • 1.5 metre lead with locking plug-in connector
  • Double adapter available for 2 sensors per chair
  • 4 levels of sensitivity with auto-calibration
  • Up to 6 monitoring periods per day
  • 10, 20 or 50 minute out-of-chair timeout options
  • Chair Sensor Part No. ZCS859
  • Compatible with Tynetec Sensor Controller

£259.82

Radio Door Contact

The Door Contacts can be used to monitor any controlled door. If the door is opened an alarm call will be transmitted immediately.

Features include

  • Surface mount single gang pattress
  • N/O surface mount door contacts supplied
  • 5 years battery life (typical)
  • Daily battery self test & low battery reporting
  • Dimensions: : 87 x 87 x 40 mm (HxWxD)
  • Door Contacts Part No. ZXT434
  • Compatible with SayPhone, Advent xt & Altec Response

Altec 169Mhz Carbon Monoxide Detector

Carbon Monoxide Detectors should be wall mounted above door height in rooms that contain a fuel burning appliance. Do not fit in bathrooms, directly above cookers or in draughty areas. If a dangerous level of carbon monoxide is detected a local alarm will sound and an alarm call will be transmitted.

Features include

  • Electrochemical Cell sensor
  • 85 dB sounder, power, fault & alarm LED indicators
  • Test/Hush button
  • Monthly self test & fault warning feature
  • 5 years detector life (inc battery)
  • Daily battery self test & low battery reporting
  • Dimensions: 145 x 80 x 50 mm (HxWxD)
  • Complies with BS EN 50291: 2001
  • Carbon Monoxide Detector Part No. ZXT422
  • Compatible with SayPhone, Advent xt & Altec Response

£140.91

Ambient Temperature Monitor

The Ambient Temperature Monitor should be wall mounted in the hallway or living room away from any draughts or heat sources. When used in conjunction with a PIR, this device can be used to assess whether a client is potentially at risk from hypothermia e.g. if they are not using their central heating system at night or during winter months. The unit will generate a warning signal should the temperature drop below 16 degrees C and will activate an alarm condition should the temperature fall below 10 degrees C for 30 minutes.

Features include

  • Solid state temperature sensing element
  • Lower alarm temperature: 10 degrees C for 30 minutes
  • Upper temperature threshold: 16 degrees C
  • 3 years battery life (typical) - user replaceable 3.6V Lithium
  • Daily battery self test & low battery reporting
  • Dimensions: 84 x 84 x 36 mm (HxWxD)
  • Ambient Temperature Monitor No. ZXT442
  • Compatible with SayPhone, Advent xt & Altec Response

£99.52

Bed Sensor

The Bed Sensor should be positioned across the width of the bed between the mattress and the base. Monitoring periods are set on the Sensor Controller. If the person gets into bed, then gets out again and does not return within the preset time an alarm call will be transmitted. A bedside lamp can be turned on/off automatically using a Remote Controlled Mains Switcher Kit. All "in-bed" and "out-of-bed" activity is transmitted and logged.

Features include

  • Bed sensor dimensions: 650 x 130 mm
  • 2 metre lead with locking plug-in connector
  • Double adapter available for 2 sensors per bed
  • 4 levels of sensitivity with auto-calibration
  • Up to 6 monitoring periods per day
  • 10, 20 or 50 minute out-of-bed timeout options
  • Bed Sensor Part No. ZCS844
  • Compatible with Tynetec Sensor Controller

£279.02

Double Adaptor

The Double Adapter can be used to connect 2 Bed Sensors (i.e. in a double bed) or 2 Pressure Mats/Door Contacts to a single Sensor Controller.

Features Include

  • Fully connected RJ45 splitter
  • Simple plug-in connection
  • Double Adapter Part No. P10285
  • Compatible with Tynetec Sensor Controller

£14.48