Altec 169Mhz Fall Detector

Altec 169Mhz Fall Detector

Our Price £120.38
Reward Points 601
Quantity

Manufacturer Tynetec

Description

Not only can it automatically detect a fall but it can also be used to detect stumbles, trips or recovered falls. If a fall is detected the unit will enter a pre-alarm state indicated by fast beeps and a green flashing LED. If the unit is not returned to the vertical position during the pre-alarm period, an emergency alarm call will be made via an At Home Alarm Unit or Advent xt Grouped System. This results in a flashing red LED on the fall detector.

Where a stumble or a trip is detected, the unit logs this information to either a SayPhone 21 At Home Alarm unit or an Advent xt Grouped System. The data can then be accessed and analysed using Tynetec's Altera Care Software. This can then be used to look for early intervention opportunities that can ultimately lead to a reduction in emergency hospital admissions.

A normal alarm call can be made at any time by pressing the red button.

Features include

  • Solid state dual axis accelerometer sensor
  • 5 user selectable levels of sensitivity
  • 3 event logs; impacts, pre-alarms & alarms
  • 1 year battery life (typical) - user replaceable 3.6V Lithium
  • Daily battery self test & low battery reporting
  • Dimensions: 85 x 56 x 20 mm (H x W x D)
  • Weight: 68 grams
  • Range: 75 metres (typical)
  • Fall Detector Part No. ZXT410
  • Optional Elasticated Belt Part No. YW9946
  • Compatible with SayPhone, Advent xt & Altec Response

Related Products...

Altec 169 Mhz Temp Extreme Sensor

The Temperature Extreme Sensor should be wall mounted in the hallway or living room away from any draughts or heat sources. This will provide early warning of extreme low or high household temperatures which could result in the occupier suffering hypothermia or dehydration. In addition, the building will also be protected against burst pipes or potential fire hazards.

Features include

  • Solid state temperature sensing element
  • Lower alarm temperature: 5 degrees C for 30 minutes
  • Upper alarm temperature: 30 degrees C for 5 minutes
  • Rate of rise alarm temperature: 8 degrees C per minute
  • 3 years battery life (typical) - user replaceable 3.6V Lithium
  • Daily battery self test & low battery reporting
  • Dimensions: 84 x 84 x 36 mm (HxWxD)
  • Temperature Extreme Sensor Part No. ZXT426
  • Compatible with SayPhone, Advent xt & Altec Response

£99.52

Bed Sensor

The Bed Sensor should be positioned across the width of the bed between the mattress and the base. Monitoring periods are set on the Sensor Controller. If the person gets into bed, then gets out again and does not return within the preset time an alarm call will be transmitted. A bedside lamp can be turned on/off automatically using a Remote Controlled Mains Switcher Kit. All "in-bed" and "out-of-bed" activity is transmitted and logged.

Features include

  • Bed sensor dimensions: 650 x 130 mm
  • 2 metre lead with locking plug-in connector
  • Double adapter available for 2 sensors per bed
  • 4 levels of sensitivity with auto-calibration
  • Up to 6 monitoring periods per day
  • 10, 20 or 50 minute out-of-bed timeout options
  • Bed Sensor Part No. ZCS844
  • Compatible with Tynetec Sensor Controller

£279.02

Wander Alarm

The Keypad should be wall mounted within the dwelling with the contacts wired to the door and the mains adapter plugged into a 13A socket. Before the Carer leaves they enter a code to start the exit time period. When the exit time period expires the door is armed. When the door is opened the entry time period starts. If the code is not entered within the entry time an alarm call will be transmitted.

Features include

  • Programmable 4 digit arm/disarm code
  • Programmable entry & exit times
  • Integral entry/exit sounder
  • Instant alarm zone option
  • Flip-cover & illuminated keypad
  • Test facility
  • Supplied with mains adapter & door contacts
  • 5 years transmitter battery life (typical)
  • Daily battery self test & low battery reporting
  • Dimensions: 135 x 90 x 27 mm (HxWxD)
  • Wandering Alarm Part No. ZXT433
  • Compatible with SayPhone, Advent xt & Altec Response

Altec 169Mhz R.N.I.D Smoke Alarm Kit

The R.N.I.D. Smoke Alarm Kit is designed exclusively for deaf and hard of hearing people. If a fire is detected the Smoke Alarm sounds, the Strobe Light flashes, the Pillow Pad vibrates and an alarm call is transmitted. The Control Centre or Local manager can assess the risk before contacting the Emergency Services.

Features include

  • Optical smoke detector with integral sounder
  • Table/wall mount unit with integral strobe
  • 100mm diameter vibrating pillow pad
  • Fault monitoring with LED status indication and Test button
  • Plug-in mains adapter with 100 hours battery standby
  • 5 years Transmitter battery life (typical)
  • Daily battery self test & low battery reporting
  • Complies with BS5446-3:2005
  • R.N.I.D. Smoke Alarm Kit Part No. ZXT437
  • Compatible with SayPhone, Advent xt & Altec Response

£293.05

Epilespy Monitor

The Epilepsy Monitor bed sensor pads should be positioned under the mattress to detect arm and leg movements. If a Tonic Clonic seizure is detected in the bed an alarm call is transmitted.

Features include

  • 2 under mattress sensor pads
  • Sophisticated digital processor
  • 3 sensitivity settings
  • LED indication of sensitivity setting
  • Supplied with Mains Adapter
  • 5 Years Transmitter battery life (typical)
  • Daily battery self test & low battery reporting
  • Dimensions: 125 x 69 x 24 mm (HxWxD)
  • Epilepsy Monitor Part No. ZXT441
  • Compatible with SayPhone, Advent xt & Altec Response

Altec 169Mhz Heat Detector

Heat Detectors should be ceiling mounted in kitchens or areas with high levels of fumes or dust, they are not suitable for bathrooms or areas of high humidity. When activated a local alarm will sound and an alarm call will be transmitted. The Control Centre or Local Manager can speak with the resident and assess the risk before contacting the Emergency Services.

Features include

  • Fast responding Thermistor sensor
  • 85 dB sounder
  • Test Button and status LED indicator
  • 1 year battery life (typical) - user replaceable 9V PP3
  • Daily battery self test & low battery reporting
  • Dimensions: 120 x 135 x 55 mm (HxWxD)
  • Complies with BS 415: 1990
  • Heat Detector Part No. ZXT421
  • Compatible with SayPhone, Advent xt & Altec Response

£100.71

Altec 169Mhz Carbon Monoxide Detector

Carbon Monoxide Detectors should be wall mounted above door height in rooms that contain a fuel burning appliance. Do not fit in bathrooms, directly above cookers or in draughty areas. If a dangerous level of carbon monoxide is detected a local alarm will sound and an alarm call will be transmitted.

Features include

  • Electrochemical Cell sensor
  • 85 dB sounder, power, fault & alarm LED indicators
  • Test/Hush button
  • Monthly self test & fault warning feature
  • 5 years detector life (inc battery)
  • Daily battery self test & low battery reporting
  • Dimensions: 145 x 80 x 50 mm (HxWxD)
  • Complies with BS EN 50291: 2001
  • Carbon Monoxide Detector Part No. ZXT422
  • Compatible with SayPhone, Advent xt & Altec Response

£140.91

Radio Door Contact

The Door Contacts can be used to monitor any controlled door. If the door is opened an alarm call will be transmitted immediately.

Features include

  • Surface mount single gang pattress
  • N/O surface mount door contacts supplied
  • 5 years battery life (typical)
  • Daily battery self test & low battery reporting
  • Dimensions: : 87 x 87 x 40 mm (HxWxD)
  • Door Contacts Part No. ZXT434
  • Compatible with SayPhone, Advent xt & Altec Response

Vibrating Pad

The Vibrating Pad can be used under a pillow or cushion to alert hard of hearing residents when the Local Manager or Control Centre is trying to contact them.

Features include

  • 100mm diameter vibrating pad
  • 1.5 metre lead with locking jack plug
  • Supplied with single gang wall plate & jack socket
  • Triggered automatically by a call to an Advent xt intercom
  • Connects to Strobe Light or separate interface board
  • Vibrating Pad Part No. W00360
  • Optional interface (if used without strobe) Part No. A00452
  • Compatible with Advent XT systems only

More...