The website uses cookies to allow us to better understand how the site is used. By continuing to use this site, you consent to this policy. Click to learn more. 
    
 

CS1 Ceiling Pull Switch

CS1 Ceiling Pull Switch

Share
Our Price £10.50
Reward Points 52
Quantity

Description

Specifically developed to give alarms from bathrooms and toilets. The unit is ceiling mounted and features a floor length cord terminated with two easy to use G loops. It also incorporates twin integral reassurance indicators, which flash to confirm a call has been generated.

Related Products...

L634 Network Input/Output Module

The L634 is used to interface an external device to the Intercall system network. The unit features three input triggers: two non-latching and one remote reset and two outputs; Re-assurance LED & open collector which can be used to trigger external equipment for normal or emergency calls. Typical applications include telephone ring detectors, contacts from fire alarm or other control panels or input from remote contacts etc. It may also be used to link two independent Intercall systems together to allo signalling, such that an active alarm on one system triggers a call on the other system and vice versa.

£75.00

Fused Junction Board

The FJB2 provides four 'spur' outputs from the network spine with each output incorporating an over current/voltage and reverse polarity protection device. A front panel mounted red/green LED indicates the condition of the internal fuses and continuously monitors the network data signals. Individual fuse failure LEDs are mounted on the reverse of the unit and in the event of cable fault, on one of the outputs, the 'spur' will be isolated without disbaling the entire cable network.

£37.00

KS1 Isolating Keyswitch

Used to isolate monitoring devices such as PIR1 or door contact.

£22.00

L622M Standard Call Point with Magnetic Reset

The L622M is the magnetic reset version of the standard call point. It is non-audio and can generate up to 6 independent call levels indicated by the twin colour re-assurance LED. The 'call follower' sounder whih is activated when the call point is in 'staff present' mode, alerts staff to other calls on the system. The jack socket will accept any closing contact input from pear leads, pressure mats, radio triggers and a host of other trigger devices.

£65.00

LBAT Backup Battery

12V 2.1aH battery for L717, L617 and L737 power supply unit.

£25.00

L746 Overdoor Light

These are normally positioned above doors in a corridor to indicate the status of the call point(s) within each room. The L746 can also be used to monitor several call points for end of corridor indication, or as a 'follow me' light. Each unit is fitted with twin ultra-bright LEDs which mimic the reassurance indicator on the call points. Also available with an integral sounder alarm (L746S).

£32.50

L628 LCD Display Units

Designed to give clear indication and alarm at every monitoring location. The unit features an LCD display with backlight, multi-level adjustable alarm, day/night volume control, 'priority' alarm tone for specific call locations, configuration menus and an output which can be connected to trigger external equipment. All displays work identically but can be configured on-site to operate independently.

£149.00

L747SL Serial Lead

Serial lead for use with L747 Universal system interface and either CMS Lite or RFTX alphanumeric paging system.

£50.00

L737 Booster PSU

The Booster Power Supply unit is designed to increase the permitted number of units and qunatity of cable that an be used on any one system. Only one master power supply may be connected on any one system but several booster units may be connected as required. Booster power supply unit to be used in conjunction with 617 and 717 power supply units.

£400.00

More...

Send to Friend

: *
: *
: *
Type the letters you see in the picture:
Captcha

*