The website uses cookies to allow us to better understand how the site is used. By continuing to use this site, you consent to this policy. Click to learn more. 
    
 

CS1 Ceiling Pull Switch

CS1 Ceiling Pull Switch

Our Price £10.50
Reward Points 52
Quantity

Description

Specifically developed to give alarms from bathrooms and toilets. The unit is ceiling mounted and features a floor length cord terminated with two easy to use G loops. It also incorporates twin integral reassurance indicators, which flash to confirm a call has been generated.

Related Products...

M1 Magnetic Door Contact

Installed in conjunction with door monitoring unit or call point and isolation switches. Activates paired call point when door is opened.

£12.00

PIR1 Passive Infra Red Bed Monitor

If you need to monitor a resident's bed and alert staff when he or she is on the move, the PIR1 bed monitor will detect movement and alert the staff. However, the bed itself is 'masked' out of the range of the detector so that it only monitors movement outside the bed area. Any movement within the receiver's range will activate a call, and trigger the call point.

£41.50

Fused Junction Board

The FJB2 provides four 'spur' outputs from the network spine with each output incorporating an over current/voltage and reverse polarity protection device. A front panel mounted red/green LED indicates the condition of the internal fuses and continuously monitors the network data signals. Individual fuse failure LEDs are mounted on the reverse of the unit and in the event of cable fault, on one of the outputs, the 'spur' will be isolated without disbaling the entire cable network.

£38.50

L747 Universal System Interface

The L747 Universal System Interface is used to output system activity in three formats: Printer Mode is used with the DU414 Thermal Printer to provide a printed record of system events., with date and time. Pager mode is used with the RFTX Alphanumeric paging equipment to provide alphanumeric paging output. PC mode is used with the CMSLite Software package designed to manage resident call information.

£450.00

SW1 Day/Night Volume Control Switch

Manual control switch to allow volumes to be quieter at night or when required.

£25.00

LBAT Backup Battery

12V 2.1aH battery for L717, L617 and L737 power supply unit.

£25.00

SCP Slave Call Point

Designed for use in one room or ward where each individual bed doesn't need a separate identity on the call system. The unit features a call button, pear lead jack socket and re-assurance indicator.

Units must be connected to a standard call point to generate the call identity and to provide the reset. Slave call points can only generate a standard call from either the call button or pear lead socket.

£24.00

L746S Addressable Overdoor Light with Sounder

These are normally positioned above doors in a corridor to indicate the status of the call point(s) within each room. The L746s can also be used to monitor several call points for end of corridor indication, or as a 'follow me' light. Each unit is fitted with twin ultra-bright LEDs which mimic the reassurance indicator on the call points. The sounder mimics the LCD display sounding patterns.

£44.50

L634 Network Input/Output Module

The L634 is used to interface an external device to the Intercall system network. The unit features three input triggers: two non-latching and one remote reset and two outputs; Re-assurance LED & open collector which can be used to trigger external equipment for normal or emergency calls. Typical applications include telephone ring detectors, contacts from fire alarm or other control panels or input from remote contacts etc. It may also be used to link two independent Intercall systems together to allo signalling, such that an active alarm on one system triggers a call on the other system and vice versa.

£75.00

More...

Send to Friend

: *
: *
: *
Type the letters you see in the picture:
Captcha

*