Intercall Nursecall 600

intercall 600 nursecall systems uk

The Intercall 600 system is currently the best-selling non-speech nursecall system in the UK, and the only one to be recommended by the National Care Association.

Its success is in its simplicity:

The Intercall 600 system is easy to install with a simple two-wire system and can be retro-fitted easily to existing wiring. It is designed to be completely user-friendly for both staff and patients alike. What's more, with five call levels, programmable text, call logging and the ability to incorporate up to 215 call points, the Intercall 600 system is one of the most comprehensive systems on the market.

Each call unit is equipped with staff presence facillity enabling staff to be located via any of the visual display units, a powerfull aid especially during the night when less staff are on duty.

The Liquid Crystal Display units give clear textual indication of call priority, location and the identity of the caller, together with audible indication of the call type, giving the care manager total control over every situation that arises within the home or hospital.

Door Monitoring is available, whether it be for external doors or drugs cabinets. This allows controlled management or notification of egress from the building or any unauthorised access to perscribed medicins.

A full dementia package is an optional extra.

Main Features

  • Non-speech based
  • Multi-level alarms - Call, Assistance, Emergency, Priority
  • Door monitoring
  • IP based power supply with full user interface
  • Accessories available

Installation & Operation GuideMake an Enquiry


7700 TCP/IP Power Supply

7700 TCP/IP Power Supply

7700

Transmission Control Protocol / Internet Protocol is the basic communication language or protocol of the internet. Information is broken down into small packets of all shapes and sizes and transmitted around the network or internet, which allows for data to be transferred quickly and efficiently between a variety of networks.

Via TCP/IP connection, Intercall's L7700 Power supply has the ability to link with many third party devices, such as IP DECT Phones, IP Message Pagers, PDA's, and front end GUI software.

The IP power supply comes complete with integral call logging.

£550.00

Quantity
12V 12 aH Battery for Black Box L7700 Power Supply

12V 12 aH Battery for Black Box L7700 Power Supply

BAT2

Back-up battery for Intercall 7717 and 7700 power supplies. Also compatible with other PSUs, e.g. 12V 5amp access control supplies.

£40.00

Quantity
617 Power Supply

617 Power Supply

617

For use as replacement for older 600 systems where 717 is not compatible.

The main power and control unit for the Intercall 600 system. It connects to the mains supply and incorporates full battery back up to safeguard the system in the event of a mains supply failure. It also stores the text programming information and can be used to configure the system by simply connecting a laptop computer. An alternative power supply unit is required for larger installations and is designed to increase the permitted number of units and quantity of cable allowed on one system.

£500.00

Quantity
LBAT Backup Battery for Grey Box Power Supplies

LBAT Backup Battery for Grey Box Power Supplies

LBAT

12V 2.1aH battery for L717, L617 and L737 power supply unit.

£25.00

Quantity
L737 Booster PSU

L737 Booster PSU

L737

The Booster Power Supply unit is designed to increase the permitted number of units and qunatity of cable that an be used on any one system. Only one master power supply may be connected on any one system but several booster units may be connected as required. Booster power supply unit to be used in conjunction with 617 and 717 power supply units.

£500.00

Quantity
SW1 Day/Night Volume Control Switch

SW1 Day/Night Volume Control Switch

SW1

Manual control switch to allow volumes to be quieter at night or when required.

£25.00

Quantity
Fused Junction Board

Fused Junction Board

FJB2

The FJB2 provides four 'spur' outputs from the network spine with each output incorporating an over current/voltage and reverse polarity protection device. A front panel mounted red/green LED indicates the condition of the internal fuses and continuously monitors the network data signals. Individual fuse failure LEDs are mounted on the reverse of the unit and in the event of cable fault, on one of the outputs, the 'spur' will be isolated without disbaling the entire cable network.

£38.50

Quantity
L628 LCD Display Units

L628 LCD Display Units

L628

Designed to give clear indication and alarm at every monitoring location. The unit features an LCD display with backlight, multi-level adjustable alarm, day/night volume control, 'priority' alarm tone for specific call locations, configuration menus and an output which can be connected to trigger external equipment. All displays work identically but can be configured on-site to operate independently.

£155.00

Quantity
L714 Remote Sounder with Relay

L714 Remote Sounder with Relay

L714

If you need an audible alarm to attract attention, but don't need an indication of the call location, the L714 is the simple solution. The sounder is similar in operation to a display unit with a multi level alarm, but has limited zoning facilities. Any assistance or emergency call on the system will over-ride the standard call tone. A built-in relay provides normally open and normally closed 'dry' contacts, which can be used to trigger auxiliary devices.

£77.50

Quantity
L746 Overdoor Light

L746 Overdoor Light

L746

These are normally positioned above doors in a corridor to indicate the status of the call point(s) within each room. The L746 can also be used to monitor several call points for end of corridor indication, or as a 'follow me' light. Each unit is fitted with twin ultra-bright LEDs which mimic the reassurance indicator on the call points. Also available with an integral sounder alarm (L746S).

£33.50

Quantity
L746S Addressable Overdoor Light with Sounder

L746S Addressable Overdoor Light with Sounder

L746s

These are normally positioned above doors in a corridor to indicate the status of the call point(s) within each room. The L746s can also be used to monitor several call points for end of corridor indication, or as a 'follow me' light. Each unit is fitted with twin ultra-bright LEDs which mimic the reassurance indicator on the call points. The sounder mimics the LCD display sounding patterns.

£44.50

Quantity
L622 Standard Call Point

L622 Standard Call Point

L622

A call point is needed for every individual call location on the system. Every L622 unit features five levels of call, multi-colour re-assurance LED alerts and a 'call follower' sounder. The jack socket accepts inputs from a wide range of triggering devices such as pear leads, pressure mats and portable radio triggers. A magnetic reset option is also available (order code L622M) which only allows the reset function to be activated by the use of a magnetic key.

£41.50

Quantity
L722 Non Audio Call Point

L722 Non Audio Call Point

L722

Specifically developed for bathrooms, toilets and other areas where the intercom facility is not require. The L722 is a Non-Audio call Poin, which incorporates 3 levels of call, Standard, Assistance and Emergency. The unit also features an infra red receiver and reassurance LED.

The unit will accept inputs from a wide range of triggering devices including pear leads, air switches, pressure mats etc. The unit may be flush or surface-mounted using standard electrical backboxes.

£56.00

Quantity
L730 Slave Infra-Red Unit

L730 Slave Infra-Red Unit

L730

Slave infra-red receiver which can be linked into other call points.

£46.50

Quantity
TIR4 Infra Red Trigger

TIR4 Infra Red Trigger

TIR4

Designed to be worn by residents or staff, the unit can generated a Nursecall activation with the simple press of a button. This is especially ideal in large lounges or common rooms to generate an 'help' call, whereby it is possible not only to identify the call location but also the individual caller.

Note: this is only usable on 700 systems.

£37.50

Quantity
TIR4 / TRF4 Trigger Battery Replacement

TIR4 / TRF4 Trigger Battery Replacement

TIR4-TRF4-BATTERY

TIR4 or TRF4 Trigger Battery Replacement x 1 - MN21

£2.25

Quantity
L622M Standard Call Point with Magnetic Reset

L622M Standard Call Point with Magnetic Reset

622M

The L622M is the magnetic reset version of the standard call point. It is non-audio and can generate up to 6 independent call levels indicated by the twin colour re-assurance LED. The 'call follower' sounder whih is activated when the call point is in 'staff present' mode, alerts staff to other calls on the system. The jack socket will accept any closing contact input from pear leads, pressure mats, radio triggers and a host of other trigger devices.

£72.50

Quantity
SCP Slave Call Point

SCP Slave Call Point

SCP

Designed for use in one room or ward where each individual bed doesn't need a separate identity on the call system. The unit features a call button, pear lead jack socket and re-assurance indicator.

Units must be connected to a standard call point to generate the call identity and to provide the reset. Slave call points can only generate a standard call from either the call button or pear lead socket.

£24.00

Quantity
SRP Slave Reset Point

SRP Slave Reset Point

SRP

Slave reset/present points are normally located by the door of a bedroom to enable staff to reset the call point and to register as staff present away from the patient call point.

£24.00

Quantity
PIR1 Passive Infra Red Bed Monitor

PIR1 Passive Infra Red Bed Monitor

PIR1

If you need to monitor a resident's bed and alert staff when he or she is on the move, the PIR1 bed monitor will detect movement and alert the staff. However, the bed itself is 'masked' out of the range of the detector so that it only monitors movement outside the bed area. Any movement within the receiver's range will activate a call, and trigger the call point.

£41.50

Quantity
KS1 Isolating Keyswitch

KS1 Isolating Keyswitch

KS1

Used to isolate monitoring devices such as PIR1 or door contact.

£25.00

Quantity
L733 Door Monitoring/Access Control Point

L733 Door Monitoring/Access Control Point

L733

If you need to protect fire doors, entrance & exit doors or other sensitive areas, the L733 is the ideal solution. The unit is controlled with a key token, which performs all functions when brought near the token detection area on the front panel. The unit also features an integral 20-second exit timer with audible bleep and mode jumper to prevent sensitive or dangerous exit doors being permanently left open.

£60.00

Quantity
M1 Magnetic Door Contact

M1 Magnetic Door Contact

M1

Installed in conjunction with door monitoring unit or call point and isolation switches. Activates paired call point when door is opened.

£12.00

Quantity
CS1 Ceiling Pull Switch

CS1 Ceiling Pull Switch

CS1

Specifically developed to give alarms from bathrooms and toilets. The unit is ceiling mounted and features a floor length cord terminated with two easy to use G loops. It also incorporates twin integral reassurance indicators, which flash to confirm a call has been generated.

£10.50

Quantity
L634 Network Input/Output Module

L634 Network Input/Output Module

L634

The L634 is used to interface an external device to the Intercall system network. The unit features three input triggers: two non-latching and one remote reset and two outputs; Re-assurance LED & open collector which can be used to trigger external equipment for normal or emergency calls. Typical applications include telephone ring detectors, contacts from fire alarm or other control panels or input from remote contacts etc. It may also be used to link two independent Intercall systems together to allo signalling, such that an active alarm on one system triggers a call on the other system and vice versa.

£75.00

Quantity
L747 Universal System Interface

L747 Universal System Interface

747

The L747 Universal System Interface is used to output system activity in three formats: Printer Mode is used with the DU414 Thermal Printer to provide a printed record of system events., with date and time. Pager mode is used with the RFTX Alphanumeric paging equipment to provide alphanumeric paging output. PC mode is used with the CMSLite Software package designed to manage resident call information.

£450.00

Quantity
L747SL Serial Lead

L747SL Serial Lead

747SL

Serial lead for use with L747 Universal system interface and either CMS Lite or RFTX alphanumeric paging system.

£60.00

Quantity
The website uses cookies to allow us to better understand how the site is used. By continuing to use this site, you consent to this policy.