Intercall Nursecall 700

intercall 700 nursecall systems uk

Intercall's 700 system, which has all the prime features of the 600 range, with the added functionality of Audio Speech and Infra-Red technology.

All 700 call units have an integral infra-red receiver, which together with a pendant trigger can generate a remote activation, useful when movement is restricted, or if an accident occurs. Not only can the display accurately give the location, but can also indicate the calling resident.

Two way speech can be generated in two scenarios i) Display to Speech Call point, where the carer can converse with the resident prior to attending, or ii) Display to Display where staff can page/talk to each other.

With the introduction of the new networked I/P based power supply, the control of the NurseCall system is at your fingertips. All parameters including Call logging can be accessed from any PC on the LAN, which gives full control back to the home.

There are numerous communication modes to receive system calls. Firstly, using the Alphanumeric displays, normally positioned with corridors, Nurse Stations, Lounges etc.

Secondly, a message can be transmitted to a pager or to an IP DECT telephone, providing information which mimics the displays.

Main Features

  • Speech or non-speech available
  • Multi-level alarms - Call, Assistance, Emergency, Priority, Staff attack
  • Door monitoring
  • IP based power supply with full user interface
  • Infra red technology
  • Accessories available

Installation & Operation Guide Make an Enquiry


7700 TCP/IP Power Supply

7700 TCP/IP Power Supply

7700

Transmission Control Protocol / Internet Protocol is the basic communication language or protocol of the internet. Information is broken down into small packets of all shapes and sizes and transmitted around the network or internet, which allows for data to be transferred quickly and efficiently between a variety of networks.

Via TCP/IP connection, Intercall's L7700 Power supply has the ability to link with many third party devices, such as IP DECT Phones, IP Message Pagers, PDA's, and front end GUI software.

The IP power supply comes complete with integral call logging.

£550.00

Quantity
12V 12 aH Battery for Black Box L7700 Power Supply

12V 12 aH Battery for Black Box L7700 Power Supply

BAT2

Back-up battery for Intercall 7717 and 7700 power supplies. Also compatible with other PSUs, e.g. 12V 5amp access control supplies.

£40.00

Quantity
L717 Power Supply

L717 Power Supply

L717

The main power and control unit for the Intercall 600 system. It connects to the mains supply and incorporates full battery back up to safeguard the system in the event of a mains supply failure. It also stores the text programming information and can be used to configure the system by simply connecting a laptop computer.

An alternative power supply unit is required for larger installations and is designed to increase the permitted number of units and quantity of cable allowed on one system.

£250.00

Quantity
LBAT Backup Battery for Grey Box Power Supplies

LBAT Backup Battery for Grey Box Power Supplies

LBAT

12V 2.1aH battery for L717, L617 and L737 power supply unit.

£25.00

Quantity
SW1 Day/Night Volume Control Switch

SW1 Day/Night Volume Control Switch

SW1

Manual control switch to allow volumes to be quieter at night or when required.

£25.00

Quantity
L737 Booster PSU

L737 Booster PSU

L737

The Booster Power Supply unit is designed to increase the permitted number of units and qunatity of cable that an be used on any one system. Only one master power supply may be connected on any one system but several booster units may be connected as required. Booster power supply unit to be used in conjunction with 617 and 717 power supply units.

£500.00

Quantity
Fused Junction Board

Fused Junction Board

FJB2

The FJB2 provides four 'spur' outputs from the network spine with each output incorporating an over current/voltage and reverse polarity protection device. A front panel mounted red/green LED indicates the condition of the internal fuses and continuously monitors the network data signals. Individual fuse failure LEDs are mounted on the reverse of the unit and in the event of cable fault, on one of the outputs, the 'spur' will be isolated without disbaling the entire cable network.

£38.50

Quantity
L758 Audio Display Units

L758 Audio Display Units

L758

Positioned in areas where calls need to be shown and heard. Firstly and foremost, it provides a two-way Speech communication with the caller. A secondary feature allows an audio page facilty to all other displays and to other speech call point with staff members present.

Following activation of a call point, the display provides a description of the call type, the location. Different tones identify the varying call types.

An useful feature is the 'Find Staff' button, which allows the user to locate other staff member easily. Sound levels (Day and night) are adjustable individually and the menu offers multiple setup to the home, including zoning of areas.

£250.00

Quantity
748 Large Corridor LED Display

748 Large Corridor LED Display

748

Designed for larger homes and hospitals, the L748 features a large LED display unit that can be clearly seen and read from 5 metres away, so busy staff can easily see who is calling at a glance. Call information is clearly displayed in full alphanumeric text on the 16 character illuminated display and a built-in audible tone alerts staff to the call.

£630.00

Quantity
L714 Remote Sounder with Relay

L714 Remote Sounder with Relay

L714

If you need an audible alarm to attract attention, but don't need an indication of the call location, the L714 is the simple solution. The sounder is similar in operation to a display unit with a multi level alarm, but has limited zoning facilities. Any assistance or emergency call on the system will over-ride the standard call tone. A built-in relay provides normally open and normally closed 'dry' contacts, which can be used to trigger auxiliary devices.

£77.50

Quantity
L762 Call Display Unit

L762 Call Display Unit

L762

A combined speech call point and a built-in display. When staff are present, it will display other calls on the system in full alphanumeric text, so staff can accept calls and speak to other callers elsewhere on the system without having to leave the residents' room. This feature is especially important in larger homes or at night time when the home is running on reduced staffing levels.

£125.00

Quantity
L752 Audio Call Point

L752 Audio Call Point

L752

The L752 is an Audio call point, which gives the facilty of hands free speech. It incorporates 3 levels of call i.e. Standard Assistance and Emergency. Other features include an infra red receiver, reassurance LED and 'call follower' sounder.

It will also accept a host of triggering devices including pear leads, air switches, pressure mats etc. The unit may be flush or surface-mounted using the Intercall BB1 Backbox.

Please note this product will be discontinued and replaced with L753

£150.00

Quantity
L753 Audio Call Point

L753 Audio Call Point

L753

The L753 is an Audio call point, which gives the facilty of hands free speech. It incorporates 3 levels of call i.e. Standard Assistance and Emergency. Other features include an infra red receiver, reassurance LED and 'call follower' sounder.

It will also accept a host of triggering devices including pear leads, air switches, pressure mats etc. The unit may be flush or surface-mounted using the Intercall BB1 Backbox.

£90.00

Quantity
L746 Overdoor Light

L746 Overdoor Light

L746

These are normally positioned above doors in a corridor to indicate the status of the call point(s) within each room. The L746 can also be used to monitor several call points for end of corridor indication, or as a 'follow me' light. Each unit is fitted with twin ultra-bright LEDs which mimic the reassurance indicator on the call points. Also available with an integral sounder alarm (L746S).

£33.50

Quantity
L746S Addressable Overdoor Light with Sounder

L746S Addressable Overdoor Light with Sounder

L746s

These are normally positioned above doors in a corridor to indicate the status of the call point(s) within each room. The L746s can also be used to monitor several call points for end of corridor indication, or as a 'follow me' light. Each unit is fitted with twin ultra-bright LEDs which mimic the reassurance indicator on the call points. The sounder mimics the LCD display sounding patterns.

£44.50

Quantity
L722 Non Audio Call Point

L722 Non Audio Call Point

L722

Specifically developed for bathrooms, toilets and other areas where the intercom facility is not require. The L722 is a Non-Audio call Poin, which incorporates 3 levels of call, Standard, Assistance and Emergency. The unit also features an infra red receiver and reassurance LED.

The unit will accept inputs from a wide range of triggering devices including pear leads, air switches, pressure mats etc. The unit may be flush or surface-mounted using standard electrical backboxes.

£56.00

Quantity
TIR4 Infra Red Trigger

TIR4 Infra Red Trigger

TIR4

Designed to be worn by residents or staff, the unit can generated a Nursecall activation with the simple press of a button. This is especially ideal in large lounges or common rooms to generate an 'help' call, whereby it is possible not only to identify the call location but also the individual caller.

Note: this is only usable on 700 systems.

£37.50

Quantity
TIR4 / TRF4 Trigger Battery Replacement

TIR4 / TRF4 Trigger Battery Replacement

TIR4-TRF4-BATTERY

TIR4 or TRF4 Trigger Battery Replacement x 1 - MN21

£2.25

Quantity
L730 Slave Infra-Red Unit

L730 Slave Infra-Red Unit

L730

Slave infra-red receiver which can be linked into other call points.

£46.50

Quantity
SCP Slave Call Point

SCP Slave Call Point

SCP

Designed for use in one room or ward where each individual bed doesn't need a separate identity on the call system. The unit features a call button, pear lead jack socket and re-assurance indicator.

Units must be connected to a standard call point to generate the call identity and to provide the reset. Slave call points can only generate a standard call from either the call button or pear lead socket.

£24.00

Quantity
SRP Slave Reset Point

SRP Slave Reset Point

SRP

Slave reset/present points are normally located by the door of a bedroom to enable staff to reset the call point and to register as staff present away from the patient call point.

£24.00

Quantity
PIR1 Passive Infra Red Bed Monitor

PIR1 Passive Infra Red Bed Monitor

PIR1

If you need to monitor a resident's bed and alert staff when he or she is on the move, the PIR1 bed monitor will detect movement and alert the staff. However, the bed itself is 'masked' out of the range of the detector so that it only monitors movement outside the bed area. Any movement within the receiver's range will activate a call, and trigger the call point.

£41.50

Quantity
KS1 Isolating Keyswitch

KS1 Isolating Keyswitch

KS1

Used to isolate monitoring devices such as PIR1 or door contact.

£25.00

Quantity
L733 Door Monitoring/Access Control Point

L733 Door Monitoring/Access Control Point

L733

If you need to protect fire doors, entrance & exit doors or other sensitive areas, the L733 is the ideal solution. The unit is controlled with a key token, which performs all functions when brought near the token detection area on the front panel. The unit also features an integral 20-second exit timer with audible bleep and mode jumper to prevent sensitive or dangerous exit doors being permanently left open.

£60.00

Quantity
M1 Magnetic Door Contact

M1 Magnetic Door Contact

M1

Installed in conjunction with door monitoring unit or call point and isolation switches. Activates paired call point when door is opened.

£12.00

Quantity
CS1 Ceiling Pull Switch

CS1 Ceiling Pull Switch

CS1

Specifically developed to give alarms from bathrooms and toilets. The unit is ceiling mounted and features a floor length cord terminated with two easy to use G loops. It also incorporates twin integral reassurance indicators, which flash to confirm a call has been generated.

£10.50

Quantity
L634 Network Input/Output Module

L634 Network Input/Output Module

L634

The L634 is used to interface an external device to the Intercall system network. The unit features three input triggers: two non-latching and one remote reset and two outputs; Re-assurance LED & open collector which can be used to trigger external equipment for normal or emergency calls. Typical applications include telephone ring detectors, contacts from fire alarm or other control panels or input from remote contacts etc. It may also be used to link two independent Intercall systems together to allo signalling, such that an active alarm on one system triggers a call on the other system and vice versa.

£75.00

Quantity
L747 Universal System Interface

L747 Universal System Interface

747

The L747 Universal System Interface is used to output system activity in three formats: Printer Mode is used with the DU414 Thermal Printer to provide a printed record of system events., with date and time. Pager mode is used with the RFTX Alphanumeric paging equipment to provide alphanumeric paging output. PC mode is used with the CMSLite Software package designed to manage resident call information.

£450.00

Quantity
L747SL Serial Lead

L747SL Serial Lead

747SL

Serial lead for use with L747 Universal system interface and either CMS Lite or RFTX alphanumeric paging system.

£60.00

Quantity
The website uses cookies to allow us to better understand how the site is used. By continuing to use this site, you consent to this policy.
More Information