Intercall Nursecall 700

Intercall Nursecall 700

intercall 700 nursecall systems uk

InterCall's most advanced system, which has all the prime features of the 600 range, with the added functionality of Audio Speech and Infra-Red technology.

All 700 call units have an integral infra-red receiver, which together with a pendant trigger can generate a remote activation, useful when movement is restricted, or if an accident occurs. Not only can the display accurately give the location, but can also indicate the calling resident.

Two way speech can be generated in two scenarios i) Display to Speech Call point, where the carer can converse with the resident prior to attending, or ii) Display to Display where staff can page/talk to each other.

With the introduction of the new networked I/P based power supply, the control of the NurseCall system is at your fingertips. All parameters including Call logging can be accessed from any PC on the LAN, which gives full control back to the home.

There are numerous communication modes to receive system calls. Firstly, using the Alphanumeric displays, normally positioned with corridors, Nurse Stations, Lounges etc.

Secondly, a message can be transmitted to a pager or to an IP DECT telephone, providing information which mimics the displays.

A recent innovation,the YAAM Graphical 3D provides a customised representation of your building and upon activation, will display the calling status and exact location where assistance is required. It also reports the location of staff who are responding to calls. The whole principle of the software is to provide users with an easy to understand visual summary of activity on the Intercall call system that can be absorbed at a glance.

Finally, a fixed IP Desktop telephone is available, which has the ability to dial individual call points, thereby opening a speech path to the patients. The phone provides audible and visual indication for all incoming calls from both speech and non speech devices. Calls are shown in order of priority and/or receipt. Staff must still attend the point of call to perform reset.

Main Features

  • PC Based or Desktop Printer Call Event Logging
  • Multi-level alarms - Call, Assistance, Emergency, Priority, Staff attack
  • Door Monitoring
  • Optional I/P Based Power Supply with full user interface
  • Accessories available

Installation & Operation GuideMake an Enquiry

Products

748 Large Corridor LED Display

Designed for larger homes and hospitals, the L748 features a large LED display unit that can be clearly seen and read from 5 metres away, so busy staff can easily see who is calling at a glance. Call information is clearly displayed in full alphanumeric text on the 16 character illuminated display and a built-in audible tone alerts staff to the call.

£590.00

7700 TCP/IP Power Supply

Transmission Control Protocol / Internet Protocol is the basic communication language or protocol of the internet. Information is broken down into small packets of all shapes and sizes and transmitted around the network or internet, which allows for data to be transferred quickly and efficiently between a variety of networks.

Via TCP/IP connection, Intercall's L7700 Power supply has the ability to link with many third party devices, such as IP DECT Phones, IP Message Pagers, PDA's, and front end GUI software.

The IP power supply comes complete with integral call logging.

£525.00

CS1 Ceiling Pull Switch

Specifically developed to give alarms from bathrooms and toilets. The unit is ceiling mounted and features a floor length cord terminated with two easy to use G loops. It also incorporates twin integral reassurance indicators, which flash to confirm a call has been generated.

£10.50

Fused Junction Board

The FJB2 provides four 'spur' outputs from the network spine with each output incorporating an over current/voltage and reverse polarity protection device. A front panel mounted red/green LED indicates the condition of the internal fuses and continuously monitors the network data signals. Individual fuse failure LEDs are mounted on the reverse of the unit and in the event of cable fault, on one of the outputs, the 'spur' will be isolated without disbaling the entire cable network.

£35.00

KS1 Isolating Keyswitch

Used to isolate monitoring devices such as PIR1 or door contact.

£20.00

L634 Network Input/Output Module

The L634 is used to interface an external device to the Intercall system network. The unit features three input triggers: two non-latching and one remote reset and two outputs; Re-assurance LED & open collector which can be used to trigger external equipment for normal or emergency calls. Typical applications include telephone ring detectors, contacts from fire alarm or other control panels or input from remote contacts etc. It may also be used to link two independent Intercall systems together to allo signalling, such that an active alarm on one system triggers a call on the other system and vice versa.

£75.00

L714 Remote Sounder with Relay

If you need an audible alarm to attract attention, but don't need an indication of the call location, the L714 is the simple solution. The sounder is similar in operation to a display unit with a multi level alarm, but has limited zoning facilities. Any assistance or emergency call on the system will over-ride the standard call tone. A built-in relay provides normally open and normally closed 'dry' contacts, which can be used to trigger auxiliary devices.

£75.00

L717 Power Supply

The main power and control unit for the Intercall 600 system. It connects to the mains supply and incorporates full battery back up to safeguard the system in the event of a mains supply failure. It also stores the text programming information and can be used to configure the system by simply connecting a laptop computer.

An alternative power supply unit is required for larger installations and is designed to increase the permitted number of units and quantity of cable allowed on one system.

£200.00

L722 Non Audio Call Point

Specifically developed for bathrooms, toilets and other areas where the intercom facility is not require. The L722 is a Non-Audio call Poin, which incorporates 3 levels of call, Standard, Assistance and Emergency. The unit also features an infra red receiver and reassurance LED.

The unit will accept inputs from a wide range of triggering devices including pear leads, air switches, pressure mats etc. The unit may be flush or surface-mounted using standard electrical backboxes.

£52.00

L730 Slave Infra-Red Unit

Slave infra-red receiver which can be linked into other call points.

£43.00

L733 Door Monitoring/Access Control Point

If you need to protect fire doors, entrance & exit doors or other sensitive areas, the L733 is the ideal solution. The unit is controlled with a key token, which performs all functions when brought near the token detection area on the front panel. The unit also features an integral 20-second exit timer with audible bleep and mode jumper to prevent sensitive or dangerous exit doors being permanently left open.

£56.00

L737 Booster PSU

The Booster Power Supply unit is designed to increase the permitted number of units and qunatity of cable that an be used on any one system. Only one master power supply may be connected on any one system but several booster units may be connected as required. Booster power supply unit to be used in conjunction with 617 and 717 power supply units.

£400.00

L746 Overdoor Light

These are normally positioned above doors in a corridor to indicate the status of the call point(s) within each room. The L746 can also be used to monitor several call points for end of corridor indication, or as a 'follow me' light. Each unit is fitted with twin ultra-bright LEDs which mimic the reassurance indicator on the call points. Also available with an integral sounder alarm (L746S).

£31.50

L746S Addressable Overdoor Light with Sounder

These are normally positioned above doors in a corridor to indicate the status of the call point(s) within each room. The L746s can also be used to monitor several call points for end of corridor indication, or as a 'follow me' light. Each unit is fitted with twin ultra-bright LEDs which mimic the reassurance indicator on the call points. The sounder mimics the LCD display sounding patterns.

£42.00

L747 Universal System Interface

The L747 Universal System Interface is used to output system activity in three formats: Printer Mode is used with the DU414 Thermal Printer to provide a printed record of system events., with date and time. Pager mode is used with the RFTX Alphanumeric paging equipment to provide alphanumeric paging output. PC mode is used with the CMSLite Software package designed to manage resident call information.

£450.00

L747SL Serial Lead

Serial lead for use with L747 Universal system interface and either CMS Lite or RFTX alphanumeric paging system.

£50.00

L752 Audio Call Point

The L752 is an Audio call point, which gives the facilty of hands free speech. It incorporates 3 levels of call i.e. Standard Assistance and Emergency. Other features include an infra red receiver, reassurance LED and 'call follower' sounder.

It will also accept a host of triggering devices including pear leads, air switches, pressure mats etc. The unit may be flush or surface-mounted using the Intercall BB1 Backbox.

Please note this product will be discontinued and replaced with L753

£135.00

L753 Audio Call Point

The L753 is an Audio call point, which gives the facilty of hands free speech. It incorporates 3 levels of call i.e. Standard Assistance and Emergency. Other features include an infra red receiver, reassurance LED and 'call follower' sounder.

It will also accept a host of triggering devices including pear leads, air switches, pressure mats etc. The unit may be flush or surface-mounted using the Intercall BB1 Backbox.

£75.00