Description

The L622M is the magnetic reset version of the standard call point. It is non-audio and can generate up to 6 independent call levels indicated by the twin colour re-assurance LED. The 'call follower' sounder whih is activated when the call point is in 'staff present' mode, alerts staff to other calls on the system. The jack socket will accept any closing contact input from pear leads, pressure mats, radio triggers and a host of other trigger devices.

Related Products...

SRP Slave Reset Point

Slave reset/present points are normally located by the door of a bedroom to enable staff to reset the call point and to register as staff present away from the patient call point.

£23.00

L622 Standard Call Point

A call point is needed for every individual call location on the system. Every L622 unit features five levels of call, multi-colour re-assurance LED alerts and a 'call follower' sounder. The jack socket accepts inputs from a wide range of triggering devices such as pear leads, pressure mats and portable radio triggers. A magnetic reset option is also available (order code L622M) which only allows the reset function to be activated by the use of a magnetic key.

£40.00

L747 Universal System Interface

The L747 Universal System Interface is used to output system activity in three formats: Printer Mode is used with the DU414 Thermal Printer to provide a printed record of system events., with date and time. Pager mode is used with the RFTX Alphanumeric paging equipment to provide alphanumeric paging output. PC mode is used with the CMSLite Software package designed to manage resident call information.

£450.00

Fused Junction Board

The FJB2 provides four 'spur' outputs from the network spine with each output incorporating an over current/voltage and reverse polarity protection device. A front panel mounted red/green LED indicates the condition of the internal fuses and continuously monitors the network data signals. Individual fuse failure LEDs are mounted on the reverse of the unit and in the event of cable fault, on one of the outputs, the 'spur' will be isolated without disbaling the entire cable network.

£37.00

PIR1 Passive Infra Red Bed Monitor

If you need to monitor a resident's bed and alert staff when he or she is on the move, the PIR1 bed monitor will detect movement and alert the staff. However, the bed itself is 'masked' out of the range of the detector so that it only monitors movement outside the bed area. Any movement within the receiver's range will activate a call, and trigger the call point.

£40.00

LBAT Backup Battery

12V 2.1aH battery for L717, L617 and L737 power supply unit.

£25.00

617 Power Supply

For use as replacement for older 600 systems where 717 is not compatible.

The main power and control unit for the Intercall 600 system. It connects to the mains supply and incorporates full battery back up to safeguard the system in the event of a mains supply failure. It also stores the text programming information and can be used to configure the system by simply connecting a laptop computer. An alternative power supply unit is required for larger installations and is designed to increase the permitted number of units and quantity of cable allowed on one system.

£400.00

L733 Door Monitoring/Access Control Point

If you need to protect fire doors, entrance & exit doors or other sensitive areas, the L733 is the ideal solution. The unit is controlled with a key token, which performs all functions when brought near the token detection area on the front panel. The unit also features an integral 20-second exit timer with audible bleep and mode jumper to prevent sensitive or dangerous exit doors being permanently left open.

£58.00

L730 Slave Infra-Red Unit

Slave infra-red receiver which can be linked into other call points.

£45.00

More...