The website uses cookies to allow us to better understand how the site is used. By continuing to use this site, you consent to this policy. Click to learn more. 
    
 

L634 Network Input/Output Module

L634 Network Input/Output Module

Share
Our Price £75.00
Reward Points 375
Quantity

Description

The L634 is used to interface an external device to the Intercall system network. The unit features three input triggers: two non-latching and one remote reset and two outputs; Re-assurance LED & open collector which can be used to trigger external equipment for normal or emergency calls. Typical applications include telephone ring detectors, contacts from fire alarm or other control panels or input from remote contacts etc. It may also be used to link two independent Intercall systems together to allo signalling, such that an active alarm on one system triggers a call on the other system and vice versa.

Related Products...

L737 Booster PSU

The Booster Power Supply unit is designed to increase the permitted number of units and qunatity of cable that an be used on any one system. Only one master power supply may be connected on any one system but several booster units may be connected as required. Booster power supply unit to be used in conjunction with 617 and 717 power supply units.

£400.00

CS1 Ceiling Pull Switch

Specifically developed to give alarms from bathrooms and toilets. The unit is ceiling mounted and features a floor length cord terminated with two easy to use G loops. It also incorporates twin integral reassurance indicators, which flash to confirm a call has been generated.

£10.50

SCP Slave Call Point

Designed for use in one room or ward where each individual bed doesn't need a separate identity on the call system. The unit features a call button, pear lead jack socket and re-assurance indicator.

Units must be connected to a standard call point to generate the call identity and to provide the reset. Slave call points can only generate a standard call from either the call button or pear lead socket.

£23.00

L747 Universal System Interface

The L747 Universal System Interface is used to output system activity in three formats: Printer Mode is used with the DU414 Thermal Printer to provide a printed record of system events., with date and time. Pager mode is used with the RFTX Alphanumeric paging equipment to provide alphanumeric paging output. PC mode is used with the CMSLite Software package designed to manage resident call information.

£450.00

L733 Door Monitoring/Access Control Point

If you need to protect fire doors, entrance & exit doors or other sensitive areas, the L733 is the ideal solution. The unit is controlled with a key token, which performs all functions when brought near the token detection area on the front panel. The unit also features an integral 20-second exit timer with audible bleep and mode jumper to prevent sensitive or dangerous exit doors being permanently left open.

£58.00

L746 Overdoor Light

These are normally positioned above doors in a corridor to indicate the status of the call point(s) within each room. The L746 can also be used to monitor several call points for end of corridor indication, or as a 'follow me' light. Each unit is fitted with twin ultra-bright LEDs which mimic the reassurance indicator on the call points. Also available with an integral sounder alarm (L746S).

£32.50

SW1 Day/Night Volume Control Switch

Manual control switch to allow volumes to be quieter at night or when required.

£25.00

LBAT Backup Battery

12V 2.1aH battery for L717, L617 and L737 power supply unit.

£25.00

SRP Slave Reset Point

Slave reset/present points are normally located by the door of a bedroom to enable staff to reset the call point and to register as staff present away from the patient call point.

£23.00

More...

Send to Friend

: *
: *
: *
Type the letters you see in the picture:
Captcha

*