Description

The Keypad should be wall mounted within the dwelling with the contacts wired to the door and the mains adapter plugged into a 13A socket. Before the Carer leaves they enter a code to start the exit time period. When the exit time period expires the door is armed. When the door is opened the entry time period starts. If the code is not entered within the entry time an alarm call will be transmitted.

Features include

  • Programmable 4 digit arm/disarm code
  • Programmable entry & exit times
  • Integral entry/exit sounder
  • Instant alarm zone option
  • Flip-cover & illuminated keypad
  • Test facility
  • Supplied with mains adapter & door contacts
  • 5 years transmitter battery life (typical)
  • Daily battery self test & low battery reporting
  • Dimensions: 135 x 90 x 27 mm (HxWxD)
  • Wandering Alarm Part No. ZXT433
  • Compatible with SayPhone, Advent xt & Altec Response

Related Products...

Strobe Light

A flashing Strobe Light is used to alert hard of hearing residents when the Local Manager or Control Centre is trying to contact them.

Features include

  • Wall mounted enclosure: 110mm diameter x 70mm deep
  • 50mm diameter blue strobe light
  • Triggered automatically by a call to an Advent xt intercom
  • Flash duration: 20 seconds
  • Advent xt Strobe Light Part No. ZSL045
  • Compatible with Advent xt systems only

£63.06

Altec 169Mhz R.N.I.D Smoke Alarm Kit

The R.N.I.D. Smoke Alarm Kit is designed exclusively for deaf and hard of hearing people. If a fire is detected the Smoke Alarm sounds, the Strobe Light flashes, the Pillow Pad vibrates and an alarm call is transmitted. The Control Centre or Local manager can assess the risk before contacting the Emergency Services.

Features include

  • Optical smoke detector with integral sounder
  • Table/wall mount unit with integral strobe
  • 100mm diameter vibrating pillow pad
  • Fault monitoring with LED status indication and Test button
  • Plug-in mains adapter with 100 hours battery standby
  • 5 years Transmitter battery life (typical)
  • Daily battery self test & low battery reporting
  • Complies with BS5446-3:2005
  • R.N.I.D. Smoke Alarm Kit Part No. ZXT437
  • Compatible with SayPhone, Advent xt & Altec Response

£293.05

Altec 169Mhz Carbon Monoxide Detector

Carbon Monoxide Detectors should be wall mounted above door height in rooms that contain a fuel burning appliance. Do not fit in bathrooms, directly above cookers or in draughty areas. If a dangerous level of carbon monoxide is detected a local alarm will sound and an alarm call will be transmitted.

Features include

  • Electrochemical Cell sensor
  • 85 dB sounder, power, fault & alarm LED indicators
  • Test/Hush button
  • Monthly self test & fault warning feature
  • 5 years detector life (inc battery)
  • Daily battery self test & low battery reporting
  • Dimensions: 145 x 80 x 50 mm (HxWxD)
  • Complies with BS EN 50291: 2001
  • Carbon Monoxide Detector Part No. ZXT422
  • Compatible with SayPhone, Advent xt & Altec Response

£140.91

Altec 169Mhz Pullcord

Ceiling Pullcord switches can be fitted in bathrooms, alongside the bed or anywhere Personal Pendants are not usually worn. An alarm call is made by simply pulling the cord once. The cord is long enough to reach floor level. Pullcord switches are available as radio or hardwired.

Features include

  • 2.7 metre orange nylon cord
  • 2 triangular orange grips
  • 5 years battery life (typical)
  • Daily battery self test & low battery reporting
  • Dimensions: 85mm diameter x 40 mm deep
  • Radio Pullcord Part No. ZXT435
  • Standard Hardwired Pullcord Part No. S00510
  • Compatible with SayPhone, Advent xt & Altec Response

£86.60

PIR Movement Detector

PIR Movement Detectors should be wall mounted at high level in the hallway or living room to monitor movement within the dwelling. PIR's can be used for activity monitoring or intruder detection;

Activity Mode; if no movement is detected within a preset period an "inactivity" alarm call will be transmitted.

Intruder Mode; if movement is detected an "intruder" alarm call will be transmitted.

Features include

  • Passive Infra Red sensor
  • Walk Test LED indicator
  • 2 minute signal time mask to prolong battery life
  • Pet Alley option to prevent false calls from pets
  • 1 year battery life (typical with 9V Lithium battery)
  • Daily battery self test & low battery reporting
  • Dimensions: 114 x 70 x 76 mm (HxWxD)
  • PIR Movement Detector Part No. ZXT425
  • Compatible with SayPhone and Advent xt systems

£73.08

Altec 169 Mhz Combined Gas & Carbon Monoxide Detector

Combined Gas & Carbon Monoxide Detectors should be wall mounted above door height in all rooms that contain a fuel burning appliance. Do not fit in bathrooms, directly above cookers or in draughty areas. If a dangerous level of gas or carbon monoxide is detected a local alarm will sound and an alarm call will be transmitted.

Features include

  • Gas - Nemoto Catalytic sensor
  • CO - Electrochemical Cell sensor
  • 85 dB sounder, power, fault, gas & CO alarm LED indicators
  • Requires 240V AC mains supply via a fused spur
  • 1 Watt power consumption
  • 5 years detector life (inc transmitter battery)
  • Daily battery self test & low battery reporting
  • Dimensions: 150 x 115 x 53 mm (HxWxD)
  • Combined Gas & CO Detector Part No. ZXT427

£264.65

Altec 169 Mhz Temp Extreme Sensor

The Temperature Extreme Sensor should be wall mounted in the hallway or living room away from any draughts or heat sources. This will provide early warning of extreme low or high household temperatures which could result in the occupier suffering hypothermia or dehydration. In addition, the building will also be protected against burst pipes or potential fire hazards.

Features include

  • Solid state temperature sensing element
  • Lower alarm temperature: 5 degrees C for 30 minutes
  • Upper alarm temperature: 30 degrees C for 5 minutes
  • Rate of rise alarm temperature: 8 degrees C per minute
  • 3 years battery life (typical) - user replaceable 3.6V Lithium
  • Daily battery self test & low battery reporting
  • Dimensions: 84 x 84 x 36 mm (HxWxD)
  • Temperature Extreme Sensor Part No. ZXT426
  • Compatible with SayPhone, Advent xt & Altec Response

£99.52

Bed Sensor

The Bed Sensor should be positioned across the width of the bed between the mattress and the base. Monitoring periods are set on the Sensor Controller. If the person gets into bed, then gets out again and does not return within the preset time an alarm call will be transmitted. A bedside lamp can be turned on/off automatically using a Remote Controlled Mains Switcher Kit. All "in-bed" and "out-of-bed" activity is transmitted and logged.

Features include

  • Bed sensor dimensions: 650 x 130 mm
  • 2 metre lead with locking plug-in connector
  • Double adapter available for 2 sensors per bed
  • 4 levels of sensitivity with auto-calibration
  • Up to 6 monitoring periods per day
  • 10, 20 or 50 minute out-of-bed timeout options
  • Bed Sensor Part No. ZCS844
  • Compatible with Tynetec Sensor Controller

£279.02

Epilespy Monitor

The Epilepsy Monitor bed sensor pads should be positioned under the mattress to detect arm and leg movements. If a Tonic Clonic seizure is detected in the bed an alarm call is transmitted.

Features include

  • 2 under mattress sensor pads
  • Sophisticated digital processor
  • 3 sensitivity settings
  • LED indication of sensitivity setting
  • Supplied with Mains Adapter
  • 5 Years Transmitter battery life (typical)
  • Daily battery self test & low battery reporting
  • Dimensions: 125 x 69 x 24 mm (HxWxD)
  • Epilepsy Monitor Part No. ZXT441
  • Compatible with SayPhone, Advent xt & Altec Response